EchoSpan® LU80-84 Ultrasonic Liquid Level Sensor Transmitter
The general purpose ultrasonic transmitter provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA signal output, and is configured via its integral push button display module. This non-contact liquid level sensor is well suited for corrosive, ultrapure, sticky or waste liquids, and is selected for bulk storage, tanker truck and neutralization tank applications.
Model :
LU80-84
The general purpose ultrasonic transmitter provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA signal output, and is configured via its integral push button display module. This non-contact liquid level sensor is well suited for corrosive, ultrapure, sticky or waste liquids, and is selected for bulk storage, tanker truck and neutralization tank applications.
| Specifications | |
| Range: |
LU80: 4” to 9.8’ (10cm to 3m) LU81: 8” to 18.0’ (20cm to 5.5m) LU83: 8” to 26.2’ (20cm to 8m) LU84: 12” to 32.8’ (30cm to 10m) |
| Accuracy: | ± 0.2% of range |
| Resolution: |
LU80: 0.019” (0.5mm) LU81/83: 0.039” (1mm) LU84: 0.078” (2mm) |
| Dead band: |
LU80: 4” (10cm) LU81/83: 8” (20cm) LU84: 12” (30cm) |
| Beam width: |
LU80: 2” (5cm) LU81/83/84: 3” (7.6cm) |
| Configuration: | Push button |
| Memory: | Non-volatile |
| Display type: | LCD, 6-digit |
| Display units: | Inch, cm and percent |
| Supply voltage: | 12-28 VDC |
| Loop resist.: | 500 Ohms @ 24 VDC |
| Signal output: | 4-20 mA, two-wire |
| Signal invert: | 4-20 mA, 20-4 mA |
| Signal fail-safe: | 4mA, 20mA, 21mA, 22mA or hold last |
| Process temp.: |
F: -7° to 140° C: -20° to 60° |
| Temp. comp.: | Automatic |
| Ambient temp.: |
F: -40° to 160° C: -40° to 71° |
| Pressure: | MWP = 30 psi (2 bar) |
| Enclosure rating: | NEMA 4X (IP65) |
| Encl. material: | Polycarbonate |
| Encl. hardware: | Brass & stainless |
| Enclosure vent: | Water tight membrane |
| Conduit entrance: | Dual, 1/2” NPT |
| Trans. material: | PVDF |
| Process mount: |
LU80: 1” NPT (1” G) LU81/83/84: 2” NPT (2” G) |
| Mount gasket: | Viton® |
| Classification: | General purpose |
| Compliance: | CE, RoHS |
• Offered in 4 measurement ranges from 9.8’ (3m) to 32.8’ (10m)
• Configuration is simple via integral push button display module
• LCD display indicates level in inches, centimeters and percentages
• Narrow 2” or 3” beam width for applications with limited measurement space
• Fail-safe intelligence and diagnostic feedback for simple troubleshooting
• PVDF transducer and NEMA 4X polycarbonate enclosure for corrosive liquids
• Automatic temperature compensation for accurate measurement
• Configuration is simple via integral push button display module
• LCD display indicates level in inches, centimeters and percentages
• Narrow 2” or 3” beam width for applications with limited measurement space
• Fail-safe intelligence and diagnostic feedback for simple troubleshooting
• PVDF transducer and NEMA 4X polycarbonate enclosure for corrosive liquids
• Automatic temperature compensation for accurate measurement
• Bulk storage
• Tanker truck
• Neutralization tank
• Tanker truck
• Neutralization tank