• EchoPod® UG01 & UG03 Reflective Ultrasonic Multi-Function Liquid Level Sensor Transmitter

EchoPod® UG01 & UG03 Reflective Ultrasonic Multi-Function Liquid Level Sensor Transmitter

The general purpose reflective ultrasonic multi-function level transmitter provides continuous level measurement up to 9.8’ (3m) with a 4-20 mA analog signal output and four relays, and is configured via our WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Each relay can be configured for alarm, automatic fill or empty functions. Select this sensor for small tanks with non-foaming and mildly vaporous media such as chemicals, water, wastewater and oil. Typical applications include day tank, IBC or drum, cooling tower, skid or machine, process tank and waste sumps.
Model : UG01&03

The general purpose reflective ultrasonic multi-function level transmitter provides continuous level measurement up to 9.8’ (3m) with a 4-20 mA analog signal output and four relays, and is configured via our WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Each relay can be configured for alarm, automatic fill or empty functions. Select this sensor for small tanks with non-foaming and mildly vaporous media such as chemicals, water, wastewater and oil. Typical applications include day tank, IBC or drum, cooling tower, skid or machine, process tank and waste sumps.
Specifications
Range: UG01: 1.5” to 4.9’ (3.8cm to 1.5m)
UG03: 4” to 9.8’ (10.1cm to 3m)
Accuracy: UG01: 0.125” (3mm)
UG03: ± 0.2% of range
Resolution: UG01: 0.019” (0.5mm)
UG03: 0.039” (1mm)
Dead band: UG01: 1.5” (3.8cm)
UG03: 4” (10.1cm)
Beam width: 2” (5cm)
Configuration: WebCal® PC Windows® USB® 2.0
Memory: Non-volatile
Supply voltage: 14-28 VDC
Max.consumption: 0.5W
Loop resistance: 500 ohms @ 24 VDC
Signal output: 4-20mA, two-wire
Signal invert: 4-20mA or 20-4mA
Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
Contact type: (4) SPST relays
Contact rating: 60 VA, 1A maximum
Contact fail-safe: Open, closed, hold last
Contact hysteresis: Selectable
Process temp.: F: -40º to 176º
C: -40º to 80º
Temp. comp.: Automatic
Ambient temp.: F: -31º to 140º
C: -35º to 60º
Pressure: 30 psi (2 bar)
Enclosure rating: Type 6P (IP68)
Encl. material: Polypropylene
Transducer type: Reflective
Transducer mat.: Polyvinylidene fluoride
Cable jacket mat.: Polyurethane
Cable type: 9-conductor, shielded
Cable length: 48” (1.2m)
Process mount: -0001: 2” NPT
-0011: 2” G
Mount gasket: -0001: N/a
-0011: Viton®
Classification: General purpose
Approval: UL 61010-1
Compliance: CE, RoHS
• Offered in 1.5m (4.9’) and 3m (9.8’) measurement ranges
• Fail-safe diagnostics with selectable relay and signal outputs
• Narrow 2” (5cm) beam width for applications with limited space
• Corrosion resistant PVDF transducer and compact PP enclosure
• Short 1.5” (3.8cm) dead band maximizes tank filling capacity
• Automatic temperature compensation from -40º to 80º C.
• Four programmable relays with embedded level control logic
  • 1 pump or valve with 3 alarms
  • 2 pumps duplexing with 2 alarms
  • 2 pumps lead-lag with 2 alarms
  • 4 independent switch point alarms
• Day tank
• IBC or drum
• Cooling tower
• Skid or machine
• Process tank
• Small waste sump