• EchoTouch® US01 & US03 Reflective Ultrasonic Liquid Level Sensor Transmitter

EchoTouch® US01 & US03 Reflective Ultrasonic Liquid Level Sensor Transmitter

The intrinsically safe reflective ultrasonic level transmitter provides continuous level measurement up to 9.8’ (3m) with a 4-20 mA analog signal output, and is configured via our WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Select this sensor for small tanks with non-foaming and mildly vaporous media such as chemicals, water, wastewater and oil. Typical applications include day tank, IBC or drum, cooling tower, skid or machine, process tank and waste sumps.
Model : US01&03

The intrinsically safe reflective ultrasonic level transmitter provides continuous level measurement up to 9.8’ (3m) with a 4-20 mA analog signal output, and is configured via our WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Select this sensor for small tanks with non-foaming and mildly vaporous media such as chemicals, water, wastewater and oil. Typical applications include day tank, IBC or drum, cooling tower, skid or machine, process tank and waste sumps.
Specifications
Range: US01: 1.5” to 4.9’ (3.8cm to 1.5m)
US03: 4” to 9.8’ (10.1cm to 3m)
Accuracy: US01: 0.125” (3mm)
US03: ± 0.2% of range
Resolution: US01: 0.019” (0.5mm)
US03: 0.039” (1mm)
Dead band: US01: 1.5” (3.8cm)
US03: 4” (10.1cm)
Beam width: 2” (5cm)
Configuration: WebCal® PC Windows® USB® 2.0
Memory: Non-volatile
Supply voltage: 14-28 VDC
Loop resistance: 500 ohms @ 24 VDC
Signal output: 4-20mA, two-wire
Signal invert: 4-20mA or 20-4mA
Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
Process temp.: F: -40º to 176º
C: -40º to 80º
Temp. comp.: Automatic
Ambient temp.: F: -31º to 140º
C: -35º to 60º
Pressure: 30 psi (2 bar)
Enclosure rating: Type 6P (IP68)
Encl. material: Polypropylene
Transducer type: Reflective
Transducer mat.: Polyvinylidene fluoride
Cable jacket mat.: Polyvinyl chloride
Cable type: 4-conductor, shielded
Cable length: 48” (1.2m)
Process mount: -0001: 2” NPT
-0011: 2” G
Mount gasket: -0001: N/a
-0011: Viton®
Classification: Intrinsically safe
Approvals: (for USA): Class I, Div 1, Groups A, B, C & D T4;
Class II, Div 1 Groups E, F & G T4;
Class III T135C;
Class I, Zone 0, IIC AEx ia T4 Ga;
Class II, Zone 20, IIIC AEx ia, T135C, Da
(for Canada): Class I, Div 1, Groups A, B, C & D T4;
Class II, Div 1 Groups E, F & G T4;
Class III T135ºC
(for IECEx): Ex ia IIC T4 Ga;
Ex ia IIIC, T135C Da;
Tamb: -40 to 80C
Entity parameters: See control drawing #610125
Compliance: CE, RoHS
• Offered in 1.5m (4.9’) and 3m (9.8’) measurement ranges
• Reflective Technology™ measures reliably with condensation
• Narrow 2” (5cm) beam width for applications with limited space
• Configuration is easy with WebCal software and USB adapter
• Short 1.5” (3.8cm) dead band maximizes tank filling capacity
• PVDF transducer and PP enclosure for corrosive environments
• Fail-safe diagnostics with selectable fail-safe signal outputs
• Type 6P (IP68) compact enclosure for small tank applications
• Automatic temperature compensation from -40º to 80º C.
• Offered in 1.5m (4.9’) and 3m (9.8’) measurement ranges
• Reflective Technology™ measures reliably with condensation
• Narrow 2” (5cm) beam width for applications with limited space
• Configuration is easy with WebCal software and USB adapter
• Short 1.5” (3.8cm) dead band maximizes tank filling capacity
• PVDF transducer and PP enclosure for corrosive environments
• Fail-safe diagnostics with selectable fail-safe signal outputs
• Type 6P (IP68) compact enclosure for small tank applications
• Automatic temperature compensation from -40º to 80º C.