EchoPro® LR11 Radar Liquid Level Sensor Transmitter
The intrinsically safe 26 GHz. pulse radar level transmitter provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or HART communicator. The non-contact liquid level sensor is intended for chemical or water storage applications in above grade metal or reinforced concrete tanks or below grade tanks of any material. Select this sensor for easy process conditions with corrosive media, light agitation, condensation or vapor, and installation in a low-profile tank adapter or flange fitting. Typical applications include chemical bulk storage and tanker trucks.
Model :
LR11
The intrinsically safe 26 GHz. pulse radar level transmitter provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or HART communicator. The non-contact liquid level sensor is intended for chemical or water storage applications in above grade metal or reinforced concrete tanks or below grade tanks of any material. Select this sensor for easy process conditions with corrosive media, light agitation, condensation or vapor, and installation in a low-profile tank adapter or flange fitting. Typical applications include chemical bulk storage and tanker trucks.
| Specifications | |
| Range: | 12” to 32.8’ (30cm to 10m) |
| Frequency: | 26 GHz. |
| Accuracy: | ± 5mm |
| Dead band: | 12” (30cm) |
| Beam angle: | 22º |
| Configuration: | Push button, HART 7 |
| Memory: | Non-volatile |
| Display type: | LCD, dot matrix |
| Display units: | Feet and meters |
| Display bar: | Percent of span |
| Display graph: | Echo signal curve |
| Supply voltage: | 21.6 to 26.4 VDC |
| Max. consumption: | 22.5 mA |
| Signal output: | 4-20 mA, two-wire, HART 7 |
| Signal invert: | 4-20 mA, 20-4 mA |
| Signal fail-safe: | 3.9 mA, 20.5 mA, 22 mA |
| Process temp.: |
F: -40º to 266º C: -40º to 130º |
| Temp. comp.: | Automatic |
| Storage temp.: |
F: -40º to 176º C: -40º to 80º |
| Pressure: | -14.5 to 43.5 psi (-1 to 3 bar) |
| Enclosure rating: | IP67 |
| Encl. material: | 316L stainless steel w/silicone gasket and PBT FR neck |
| Encl. window mat.: | Polycarbonate |
| Conduit entrance: | (1) 1/2” NPT connector |
| Antenna material: | PFA |
| Process mount: | 1-1/2” NPT |
| Classification: | Intrinsically safe |
| Approvals: |
ATEX IIG Ex ia II C T6...T3 Ga IEC Ex ia IIC T6...T3 Ga CSA Class I, Div 1, Groups A, B, C & D; Class II, Div 1, Groups E, F & G; (T6...T3); Class I Zone 0 AEx ia IIC (T6...T3) Ga & Zone 20 AEx ia IIIC (T76ºC to T146ºC) Da; Ex ia IIC (T6...T3) Ga & Ex ia IIIC (T76ºC to T146ºC) Ga |
| Certification: | FCC |
| Compliance: | CE, RoHS |
• PFA encapsulated antenna and mount for corrosive media
• Configuration via push button display or HART communicator
• 26 GHz. pulse radar is unaffected by vapor or condensation
• 12” (30cm) dead band enables utilization of the entire tank
• LCD displays level in feet or meters with percent of span bar
• Optional display mode indicates the echo signal return curve
• Fail-safe diagnostics with selectable signal fail-safe outputs
• Recognition, storage and rejection of false echo signal returns
• IP67 stainless enclosure with polycarbonate display window
• Configuration via push button display or HART communicator
• 26 GHz. pulse radar is unaffected by vapor or condensation
• 12” (30cm) dead band enables utilization of the entire tank
• LCD displays level in feet or meters with percent of span bar
• Optional display mode indicates the echo signal return curve
• Fail-safe diagnostics with selectable signal fail-safe outputs
• Recognition, storage and rejection of false echo signal returns
• IP67 stainless enclosure with polycarbonate display window
• Chemical bulk storage
• Tanker truck
• Acid tank
• Bulk tank
• Chemical feed
• Chemical tank
• Day tank
• Neutralization tank
• Hazardous area
• Tanker truck
• Acid tank
• Bulk tank
• Chemical feed
• Chemical tank
• Day tank
• Neutralization tank
• Hazardous area