Transducer
The transducer is housed in a rigid aluminium casting. An alphanumeric display and three membrane keys provide comfortable operation. Everything is designed according to requirements for user friendliness and ergonomics. Quick and easy access to the connectors is ensured. The flowmeter menu is in English, it is intuitive and allows easy configuration. All user parameters, from the flow and volume units, through the selection of displayed units, setting of the pulse and current output settings, can be easily set by a keypad. The construction of the measure unit allows four positions of the flowtube in a horizontal or vertical pipe line while the correct operation position of the stainless steel front panel with display and membrane keys is always provided.
Transducer: | COMFORT | ECONOMIC |
Display: | YES (2x16 chars) | NO |
Keypad: | YES | NO |
Measuring range: | 1 :40 ( ±0,5% for MPE standard); 1:500 (Q0=0,2% Qmax) | |
Accuracy: | ± 0.5 % (± 0.003 m/s) in range from Qmin do Qmax | |
Minimum liquid conductivity: | >5ųS/cm – common liquids; ≥20ųS/cm – demineralized water | |
Power supply: | 230 VAC (+10;−15%) 50–60Hz; optionally 120VAC, 24VAC, 24VDC | |
Power demand: | 10 VA | |
IEC 536 protection class: | I | |
Ingress protection rating: | IP67 | |
Meter finish: | powder paint (RAL 8023) | |
Ambient temperature rangé: | 0–70°C; recommended 15–55°C | |
Pulse output 1: | in range 0.0001–1600 p/dm3 (maximum value depends on flowtube inner diameter) | |
Pulse output 2: | state – signalization of the negative flow; pulse – negative volume (bidirectional flow) | |
Pulse inputs: | 2× range (0.0001–1000 p/dm3) to display flow and/or volume measured by external | |
Empty pipeline indication: | yes (optional) | |
Communication modules: | RS485, RS422, RS232, M-Bus, ... (optional) | |
Communication protocols: | SIMPLE, ModBUS, BitBUS, ASCII , MBUS | |
Analogue outputs: | 4-20 mA, 0-10 V (optional) | |
Archive: | hourly, daily, monthly, errors,.. (optional) |
- Comfortable or economical design of the transducer
- Compact or separate connecting of the flow sensors
- Large selection of flow sensor types (flanged, wafer, threaded, food industry,…)
- Wide range of applications (food, chemical, water and other industries)
- User settable displaying of the items on the display
- Setting of the flow meter direct by flowmeter´s keypad. (pulse out, analog out, type and speed of communication, dynamics of the measurement, etc.)
- Flowtube replaceability (each flowtube has its own calibration constants)
- User software FG measure for easy saving and printing of the measurent protocol, FG BVIS software for remote monitoring, …
- Bidirectional flow measurement (separate counter for each direction)
- Self-diagnostics – instrument status indicated on display
- Volumetric monitoring on up to 5 resettable flow rate totalizers (counters)
- Monitoring of maximum flow reached within a time interval
- Option to connect up to two external devices (flow meters) to pulse inputs and to display their flow rate and volume information
- Easy integration into other manufacturer’s host systems using pulse or analogue outputs, RS232,485 or MeterBUS interface…
- Optional temperature measurement module (not allowed with empty pipe detection module)
- Optional pipe detection module (el. module + third detection electrode)
- archiving of date time stamped measurement data for up to one year in non-volatile memory
- uptime records
- power failure and error condition records