• Electromagnetic Flowmeters with W or Wss flow tube – wafer design
  • Electromagnetic Flowmeters with W or Wss flow tube – wafer design

Electromagnetic Flowmeters with W or Wss flow tube – wafer design

Model : FG4000

These sensors are designed to be installed between flanges. The flowtubes are installed between two connecting flanges and tightened with bolts. They come in inner diameters from DN10 to DN150 while they have shorter installation lengths than the F (flanged) flowtubes with the same diameters. The dimensions of the wafer sensors are compatible with the sensors of the MP400, MP400 C/M, MT500,… (EESA producer).

These flowtubes are only made with Teflon liner, and with a choice from several sensing electrode materials (316L stainless steel, Hastelloy C, titanium, tantalum,…). The maximum allowable pressure of these sensors is PN25.

The flowtube contact faces have spigots that align with recesses in the connecting flanges. This arrangement ensures precise flowtube centering within the pipe thus eliminating any potential metering errors from flowtube improper installation. It is therefore useful to order the flow meters with our original installation sets that contain flanges with appropriate recesses. These flanges are also fitted with connecting terminals for earthing conductors. Installation sets may also be custom specified with respect to installation length and type of connection (DIN 11851 threading for food industry, DIN 32676 clamp, etc.)
Earthing rings are also available on request. This guarantees flawless flow meter operation at all times even for installations in plastic pipework.
All materials to be in contact with the medium under measurement are certified for permanent contact with drinking water (edibles) and hot utility water.
Our flow meters are thus convenient for all kinds of food processing applications to measure flow of drinking water, wine and related products, milk, whey, beer, and other food consumables. Besides other, they resist cleaning lyes or acids that are used in such applications on a daily basis. They furthermore meet specific requirement in most chemical facilities.


Flow meters with “Wss” flow tube /Wafer stainless steel/

The Wss (Wafer, stainless steel) flow meters have the same dimensions and parameters as the previous W-type flow meters. They too are designed to be installed between flanges. They are installed between two connecting flanges and tightened with bolts. Their flowtubes are only made with Teflon liner and with a choice from several sensing electrode materials (316L stainless steel, Hastelloy C, titanium, tantalum,…).

The difference is only in the sensor housing that is made of stainless steel. Therefore, these sensors are more suitable for measuring chemically aggressive liquids and for installation in corrosive and otherwise demanding environments.

They are made with inner diameters from DN10 to DN100 are are primarily designed for chemical and food processing applications.

The components in installation sets are all made of stainless steel. Installation sets may equally be custom specified with respect to installation length and type of connection (DIN 11851 threading for food industry, DIN 32676 clamp, etc.)

Earthing rings are also available if required.

All materials to be in contact with the medium under measurement are certified for permanent contact with drinking water (edibles) and hot utility water.

These flow meters are convenient to measure acid or alkaline solutions as well as various kinds of chemicals (lyes, acids, ammonia, hydrogen chloride, cleaning agents, …).

Transducer: COMFORT ECONOMIC
Display: YES (2x16 chars) NO
Keypad: YES NO
Measuring range: 1 :40 ( ±0,5% for MPE standard); 1:500 (Q0=0,2% Qmax)
Accuracy: ± 0.5 % (± 0.003 m/s) in range from Qmin do Qmax
Minimum liquid conductivity: >5ųS/cm – common liquids; ≥20ųS/cm – demineralized water
Power supply: 230 VAC (+10;−15%) 50–60Hz; optionally 120VAC, 24VAC, 24VDC
Power demand: 10 VA
IEC 536 protection class: I
Ingress protection rating: IP67
Meter finish: powder paint (RAL 8023)
Ambient temperature rangé: 0–70°C; recommended 15–55°C
Pulse output 1: in range 0.0001–1600 p/dm3 (maximum value depends on flowtube inner diameter)
Pulse output 2: state – signalization of the negative flow; pulse – negative volume (bidirectional flow)
Pulse inputs: 2× range (0.0001–1000 p/dm3) to display flow and/or volume measured by external
Empty pipeline indication: yes (optional)
Communication modules: RS485, RS422, RS232, M-Bus, ... (optional)
Communication protocols: SIMPLE, ModBUS, BitBUS, ASCII , MBUS
Analogue outputs: 4-20 mA, 0-10 V (optional)
Archive: hourly, daily, monthly, errors,.. (optional)

Wafer flowtube specification:

Flowtube nominal inner diameter: DN10 – DN150 (W-type)
DN10 - DN100 (Wss-type)
Flowtube liner: PTFE – teflon
Electrodes: 316L grade (1.4571) stainless steel; Hastelloy C; platinum; tantalum; titanium
Nominal pressure: PN25
Flowtube design: compact; split – 4m cabling (optionally up to 40m)
Flowtube finish: powder paint RAL 7043 (W-type)
brushed stainless steel (Wss-type)
Temperature of the measured liquid 0 - 150°C
Ingress protection rating: IP67